11 research outputs found

    Distribution network reconfiguration for loss reduction using PSO method

    Get PDF
    In recent years, the reconfiguration of the distribution network has been proclaimed as a method for realizing power savings, with virtually zero cost. The current trend is to design distribution networks with a mesh network structure, but to operate them radially. This is achieved by the establishment of an appropriate number of switchable branches which allow the realization of a radial configuration capable of supplying all of the normal defects in the box of permanent defect. The purpose of this article is to find an optimal reconfiguration using a Meta heuristic method, namely the particle swarm optimization method (PSO), to reduce active losses and voltage deviations by taking into account certain technical constraints. The validity of this method is tested on a 33-IEEE test network and the results obtained are compared with the results of basic load flow

    Modeling and Lyapunov-designed based on adaptive gain sliding mode control for wind turbines

    Get PDF
    In this paper, modeling and the Lyapunov-designed control approach are studied for the Wind Energy Conversion Systems (WECS). The objective of this study is to ensure the maximum energy production of a WECS while reducing the mechanical stress on the shafts (turbine and generator). Furthermore, the proposed control strategy aims to optimize the wind energy captured by the wind turbine operating under rating wind speed, using an Adaptive Gain Sliding Mode Control (AG-SMC). The adaptation for the sliding gain and the torque estimation are carried out using the sliding surface as an improved solution that handles the conventional sliding mode control. Furthermore, the resultant WECS control policy is relatively simple, meaning the online computational cost and time are considerably reduced. Time-domain simulation studies are performed to discuss the effectiveness of the proposed control strateg

    Sveobuhvatan pregled LVRT mogućnosti i kliznog režima upravljanja vjetroagregata spojenog na mrežu s dvostruko napajanim asinkronim generatorom

    Get PDF
    In this paper, a comprehensive review of several strategies applied to improve the Low Voltage Ride-Through (LVRT) capability is presented for grid-connected wind-turbine-driven Doubly Fed Induction Generator (DFIG). Usually, the most proposed LVRT solutions in the literature based on: hardware solutions, which increase the system costs and software solutions, which increase the control system complexity. Therefore, the main objective of this study is to take into account grid requirements over LVRT performance under grid fault conditions using software solution based on Higher Order-Sliding Mode Control (HOSMC). Effectively, this control strategy is proposed to overcome the chattering problem and the injected stator current harmonics into the grid of the classical First Order Sliding Mode (FOSMC). Furthermore, the resultant HOSMC methodology is relatively simple; where, the online computational cost and time are considerably reduced. The LVRT capacity and effectiveness of the proposed control method, compared to the conventional FOSMC, are validated by time-domain simulation studies under Matlab on a 1.5 MW wind-turbine-driven DFIG.U ovom radu, prikazan je sveobuhvatan pregled strategija primjenjenih za poboljšanje sposobnosti rada tijekom prolaznih smetnji niskog napona mreže za vjetroagregat s dvostruko napajanim asinkronim generatorom (DFIG). Uobičajeno, većina predloženih LVRT rješenja u literaturi temelji se na: hardverskim rješenjima, što povećava troškove sustava i softverskih rješenja te složenost sustava upravljanja. Stoga je glavni cilj ovog istraživanja da se uključuje i zahtjevi mreže kroz ponašanje LVRTa u uvjetima mrežnih kvarova korištenjem softverskog rješenja zasnovanoga na kliznom režimu rada višeg reda (HOSMC). Efektivno, ova upravljačka strategija je predložena kako bi se prevladali oscilacije i ubacivanje harmonika struje statora u mrežu klasičnim metodama kliznog režima rada prvog reda (FOSMC). Nadalje, rezultantna metodologija HOSMC je relativno jednostavna; gdje su online računski zahtjevi i potrebno vrijeme značajno smanjeni. LVRT kapacitet i učinkovitost predložene metode upravljanja, u usporedbi s konvencionalnim FOSMC potvrđene su simulacijama u vremenskoj domeni u Matlabu na 1.5 MW vjetroagregatu s DFIG-om

    Chemical composition, in vitro antioxidant and anti-inflammatory activities of Juniperus oxycedrus subsp. oxycedrus extracts from Algeria

    Get PDF
    This study was conducted to examine chemical compositions, the anti-oxidant and anti-inflammatory properties of methanolic and aqueous extracts from aerial parts of Juniperus oxycedrus subsp oxycedrus growing in Mascara, Algeria. The quantitative assessment indicated that methanol extract was the most concentrated in phenolic, flavonoid and tannin contents (167.77±5.12 mg GAE/g DW, 90.56±2.23 mg QE/g DE and 110.21±2.38 mg CE/g DE respectively). The chromatographic analysis by HPLC showed quantitative differences in phenolic constutents, noting that Chlorogenic acid was the major compound of both extracts. Moreover, methanolic extract exhibited the highest antioxidant activity than the aqueous extract when tested by the 1,1-diphenyl-2-picrylhydrazyl (IC50 4.45±0.001 μg/mL) and phosphomolybdenum (328.52±0.071 mg of GAE/g DW) assays. Furthermore, the in vitro anti-inflammatory activity showed a strong inhibition of albumin denaturation by the methanolic extract at different concentrations when compared to standard drug diclofenac sodium. These findings confirm the richness of Algerian Juniperus oxycedrus extracts in bioactive compounds with antioxidant and anti-inflammatory capacities. These results are compatible with the use of the plant in traditional medicine. DOI: http://dx.doi.org/10.5281/zenodo.713528

    Dual Robust Control of Grid-Connected DFIGs-Based Wind- Turbine-Systems under Unbalanced Grid Voltage Conditions

    Get PDF
    In this chapter, a comparative analysis is made for doubly-fed induction-generator (DFIG) low-voltage ride-through (LVRT) solutions. It is supposed to improve the LVRT capability of DFIG under unbalanced grid voltage conditions by hardware or software solutions. Therefore, this chapter proposes a low-cost software LVRT solution based on an efficient control scheme of DFIG driven by a wind turbine. The proposed control scheme is based on dual-sequence decomposition technique and Lyapunov-based robust control (RC) theory. Under an unbalanced grid voltage conditions, the proposed control strategy not only eliminates effectively the oscillations of the active and reactive powers exchanged between the generator and the grid but also achieves the symmetrical and sinusoidal grid currents injection. Simulation analysis under MATLAB®/Simulink® has been carried out on a 1.5 MW DFIG-based wind-turbine-systems, and the results are presented and discussed to demonstrate the feasibility and the efficiency of the control strategy for a grid-connected application under unbalanced voltage supply. The proposed dual control scheme is shown to be able to successfully mitigate torque, stator power and currents pulsations as compared with the conventional vector control based on the single control scheme

    Chemical composition and anti-arthritic activity of Anacyclus valentinus extract on adjuvant-induced arthritis in rats

    Full text link
    Anacyclus valentinus L. is a common annual plant in Algeria, known for her various therapeutic effects. In addition, the plant is used as a food condiment. We reported our investigations on the chemical compositions and the antiarthritic activity of methanolic extract of A. valentinus (MEAV). The polyphenol extraction by maceration with methanol (80%) gave yields of 17.82%. The identification by LC-MS and colorimetric assays revealed the wealth of methanolic extracts on phenolic compounds including flavonoids (52.15 mg Equ/g) and lactones. Acute oral toxicity of extract was performed in line with OECD guidelines and the lethal dose 50 was assessed greater than 2500 mg/Kg. Regarding the anti-arthritic power, rheumatoid arthritis was induced by Freund\u27s adjuvant in rats. The methanolic extract of A. valentinus presented a largest effect with weight gain, an arthritic score, thymus indices; spleen and serum parameters close to those of the control. The extract also inhibited edema and restored cartilage structure

    Speed sensor-less and robust power control of grid-connected wind turbine driven doubly fed induction generators based on flux orientation

    No full text
    The aim of this paper is to propose a power control method for Wind Energy Conversion System (WECS) using Double Fed Induction Generator (DFIG). This control strategy, based on stator flux orientation, tracks the maximum power for different wind speeds and regulates separately the active and reactive powers exchanged between the generator and the grid. The control algorithm uses Sliding Mode Control technique (SMC). The suitability of the proposed control strategy is proved in terms of efficiency maximization by including external disturbances (grid fault condition) with respect to bounded parameter variations affecting the electrical system. The estimation of the speed is based on Model Reference Adaptive System (MRAS) method. Some results of simulation are presented, discussed to prove efficiency and robustness of the DFIG control policy for WECS against external and internal perturbations with MPPT responses

    Feasibility Study of Wind Farm Grid-Connected Project in Algeria under Grid Fault Conditions Using D-Facts Devices

    No full text
    The use of renewable energy such as wind power is one of the most affordable solutions to meet the basic demand for electricity because it is the cleanest and most efficient resource. In Algeria, the highland region has considerable wind potential. However, the electrical power system located is this region is generally not powerful enough to solve the problems of voltage instability during grid fault conditions. These problems can make the connection with the eventual installation of a wind farm very difficult and inefficient. Therefore, a wind farm project in this region may require dynamic compensation devices, such as a distributed-flexible AC transmission system (D-FACTS) to improve its fault ride through (FRT) capability. This paper investigates the implementation of shunt D-FACTS, under grid fault conditions, considering the grid requirements over FRT performance and the voltage stability issue for a wind farm connected to the distribution network in the Algerian highland region. Two types of D-FACTSs considered in this paper are the distribution static VAr compensator (D-SVC) and the distribution static synchronous compensator (D-STATCOM). Some simulation results show a comparative study between the D-SVC and D-STATCOM devices connected at the point of common coupling (PCC) to support a wind farm based on a doubly fed induction generator (DFIG) under grid fault conditions. Finally, an appropriate solution to this problem is presented by sizing and giving the suitable choice of D-FACTS, while offering a feasibility study of this wind farm project by economic analysis
    corecore